SDC 2002
4.5 Color Menu
4-121
Operating Instructions - Rev. 1 / 6.2003
Control Range
“Toe”
High black compression: e.g. 20% level changes to 5%
Low black compression: e.g. 20% level changes to 12%
Linear level, no changes
Low black stretch: e.g. 20% level changes to 28%
High black stretch: e.g. 20% level changes to 35%
“Shoulder”
High white compression: e.g. 80% level changes to 95%
Low white compression: e.g. 80% level changes to 88%
Linear white, no changes
Low white stretch: e.g. 80% level changes to 70%
High white stretch: e.g. 80% level changes to 61%
3. Test
& Pattern
When Test is enabled, the yellow bar on the key is lit.
By pressing the adjacent pattern key, a drop-down menu opens, containing all
available Test Patterns.
To select a pattern, click on it.
The current selection is shown on the key display. If it reads ”HDNR Pattern”, a
SCREAM Test Pattern is active.
This function is redundant in the Monitoring and in the Home Menu.
4. 6SC
Limiter
There are 6 different limiter settings available:
Soft 108, Hard 108, Soft 102, Hard 102, Soft 100, Hard 100.
”Soft” implies smooth limiting (a knee function is applied),
”Hard” stands for signal clipping.
Value ”100” limits RGB range between 0% and 100%,
value ”102” limits RGB range between 0% and 102%,
value ”108” limits RGB range between -7% and 108%.
”Off” stands for no limitation.Click on the key and make your choice from the
drop-down menu.
Note that this limiter only affects the signal output of the 6SC Board.
This is not identical to the output signal of the telecine as the RGB signal com-
ing from the 6SC Board is processed further on.
Details, see also chapter 4.5.3 “Description of 6SC”