SDC 2002
4.3. TK Config Menu
4-41
Operating Instructions - Rev. 1 / 6.2003
”TV-PD” Image data, color graded on a TV monitor, are mapped to
Printing Density characteristic for CINEON DXR files
- e. g. used for post production systems like Inferno / Fire
(Discreet Logic) or Domino (Quantel).
TV-PD lookup table transfers the dynamic range of the TV
display into the logarithmic domain. No highlight details appear
above ~ 720
d.
black level 95
d
(10
bit)
white level 685
d
(10
bit)
highlights up to ~ 720
d
Characteristics:
data output-code value
Lookup table input
1024
d
1024
d
0
d
TV-PD
Description
TV-PD
To set up the machine for TV-PD, grade your film on your video monitor as usual,
then switch to data mode, choose TV-PD as LUT and start the transfer.
The telecine monitoring test point has to be switched to Output stage.
0% (black) on the WFM will be mapped to 95
d
,
94% (white) will be mapped to 685
d
(658mV).
The transferred data will contain all information up to approx. 109% signal level at
the waveform monitor.
In TV-PD mode, CRT GAMMA (Menu Color - Col Set)cannot be deselected be-
cause it is part of the logarithmic TV-PD transfer characteristic.
Note!
The TV-PD in Specter always requires TV LEV data with CRT GAMMA switched
“ON” at the telecine.