SDC 2002
6. Maintenance
6-22
Operating Instructions - Rev. 1 / 6.2003
6.7. THE COMOPT SOUND LAMP
The audio scanner of the film scanner is equipped with one 6V / 20W halogen
COMOPT sound lamp each (1 pc order no. 002 126 696 001) for 16mm and 35mm
COMOPT films.
The corresponding COMOPT sound lamp will be switched on automatically (de-
pending on the optical block in use), when COMOPT is selected.
29881
Plug of the
COMOPT sound lamp
Locking angle
35mm COMOPT sound lamp
16mm COMOPT sound lamp
Centering pin
35mmCOMOPTsoundoptics
16mmCOMOPTsoundoptics
16mm COMOPT audio head
Fig. 620: Audio scanner of the film scanner (opened)
1. Remove the fastening screw of the audio scanner cover and pull off the cover.
2. Pull the plug of the COMOPT sound lamp out of its socket.
3. Turn both locking angles at the lamp holder to the side and pull the defective
lamp out of the lamp holder (note mounting position).
4. Slide the new lamp all the way into the lamp holder (watch the centering pin,
avoid finger prints), close both locking angles and refit the lamp plug.
When changing a COMOPT sound lamp, slight input level losses are possible in
the respective audio channel.
This slight level loss can be compensated (if necessary) as follows: